Binary Input Objects
Showing objects from
Object
 Object Name
 Object Description
Out of
Service
Present Value
Reliability
Status
 Text
1
 upsOnBattery
 UPS on battery trap detected
N
Inactive
0
0,0,0,0
 UPS no longer on battery
2
 upsAlarmBatteryBad
 One or more batteries need replacement
N
Inactive
0
0,0,0,0
 Status Normal
3
 upsAlarmOnBattery
 Indicates when UPS is on battery
N
Inactive
0
0,0,0,0
 UPS on Utility Power
4
 upsAlarmLowBattery
 Remaining battery time less than limit
N
Inactive
0
0,0,0,0
 Status Normal
5
 upsAlarmDepletedBattery
 UPS will be unable to sustain load
N
Inactive
0
0,0,0,0
 Status Normal
6
 upsAlarmTempBad
 Temperature out of tolerance
N
Inactive
0
0,0,0,0
 Status Normal
7
 upsAlarmInputBad
 An input condition is out of tolerance
N
Inactive
0
0,0,0,0
 Status Normal
8
 upsAlarmOutputBad
 Output condition out of tolerance
N
Inactive
0
0,0,0,0
 Status Normal
9
 upsAlarmOutputOverLoad
 Output exceeds UPS capacity
N
Inactive
0
0,0,0,0
 Status Normal
 upsAlarmOnBypass
 Bypass is engaged on UPS
N
Inactive
0
0,0,0,0
 Status Normal
 upsAlarmBypassBad
 Bypass is out of tolerance
N
Inactive
0
0,0,0,0
 Status Normal
 upsAlarmOutputOffAsRequested
 UPS has shut down as requested
N
Inactive
0
0,0,0,0
 Status Normal
 upsAlarmUpsOffAsRequested
 Entire UPS has shut down as requested
N
Inactive
0
0,0,0,0
 Status Normal
 upsAlarmChargerFailed
 Problem detected with charger system
N
Inactive
0
0,0,0,0
 Status Normal
 upsAlarmUpsOutputOff
 UPS output is in the Off state
N
Inactive
0
0,0,0,0
 Status Normal
Quick Help

The object name, value, and status are shown for a list of objects starting with the number entered at the top of the page. Click Prev/Next to scroll through the list. Click on the object number in the first column to change name or out-of-service state.

The source of data for a Binary Input object will typically be reading from some other BACnet device. Click on the object number in the first column for more detail including the link to any client map providing data to this object.

Out of Service means polling for data will stop. While out of service, the present value may be written by the BACnet client. Data may be forced via this web page at any time, but will be overwritten by the next mapped client update unless the object is out of service.

Reliability codes may be any of the following:
BACnet client, device timeout (82)
BACnet client, error returned by server (83)
SNMP client, no response from agent (91)
SNMP client, agent returned 'no such name' error (92)
SNMP client, unable to parse data returned (93)
SNMP client, reply did not match request (94)
SNMP client, invalid table walk configuration (95)
SNMP client, unable to parse PDU returned (96)
SNMP client, table walk came up short on data (97)
SNMP client, agent returned error other than 'no such name' (98)

Status flags A,B,C,D indicate the following, 0 meaning not true, 1 meaning true:
A = in alarm
B = fault
C = overridden
D = out of service